Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
06/05/2025 COT - RSEL - Electrical Final  Re-inspection required 6/5/25: garbage disposal circuit tied into kitchen island, exterior plastic piping must be coated, support electrical whip at hvac, 3" clearance required at A/C condenser, 3'clearance required from regulator vent to electrical panel, Post tension stamp cannot be read, 20 min label at garage door is painted over, attic access ladder must be appropriate height. All receptacles in laundry room must be GFCI.
06/10/2025 COT - RSEL - Electrical Final  Passed 6-10-25: electrical final approved.