Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
04/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Provide plans on site prior to inspection. 4/10/2025
04/11/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass 4/11/25
1.Partial pass, HTT4s are missing nut and bolt. Pending special inspection, do not cover nut with epoxy.
2. Plan calls for CS20 straps 24" long or LSTA12.
3. Beams at framed column must have 3/8" osb on all 4 sides or plywood.
04/16/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/16/25
Pass