Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 4/11/25 1.Partial pass, HTT4s are missing nut and bolt. Pending special inspection, do not cover nut with epoxy. 2. Plan calls for CS20 straps 24" long or LSTA12. 3. Beams at framed column must have 3/8" osb on all 4 sides or plywood. |
|
| 04/23/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 4-23-25, pancake box at coach light is overfilled. There are 2-14/2 AWG wires-replace with bigger box. | |
| 04/24/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 4-24-25, over filled single gang box over refrigerator and properly block 4-gang box. | |
| 04/28/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 04/28/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | nut with epoxy. 2. Plan calls for CS20 straps 24" long or LSTA12. 3. Beams at framed column must have 3/8" osb on all 4 sides or plywood. 4-23-25, pancake box at coach light is overfilled. There are 2-14/2 AWG wires-replace with bigger box. 4-24-25, over filled single gang box over refrigerator and properly block 4-gang box. 4/28/25: properly secure NM cable at interior walls, attic access headroom clearance not met (30" required) will check final. |
|
| 04/29/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |