Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
07/10/2026 COT - RSME - Mechanical Final  Re-inspection required 07/10/2026
Line set at AC cannot be wrapped with adhesive tape, requires removable wrap with Velcro or sheet metal or similar protection to insulation (2024 IRC N1103.4 / R403.4). Cut cleanouts flush to grade. Add breaker lock to water heater breaker at main panel. Main water line has PRV - verify if tankless water heater requires expansion tank. No ladder to verify attic and equipment.
07/14/2026 COT - RSME - Mechanical Final  Passed 07/14/2026
Corrections made.