Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
12/11/2024 COT - RSBU - Roof Nailing  Re-inspection required 12-11-24, add nails to shear wall at owners suite, missing anchor bolts throughout-areas marked, add shot pin to marked location near laundry room, loose roof panel by bedroom 4 (marked it on the slab). STOPPED INSPECTION-ADDITIONAL ITEMS MSY BE NOTED.
12/16/2024 COT - RSBU - Roof Nailing  Re-inspection required 12-16-24, missing bracing on truss H10A on W7& on each side of W8. Nail down all h-25's on interior load bearing walls by intermediate inspection. Also,Unable to check roof nailing. Roof is partially loaded with several rolls of tar paper and a pellet of materials over garage area. Therefore, submit a letter to the city stating roof nailing meets code requirements/ nailed per approved plans or remove items and reschedule an inspection. If you opt for the letter then it shall be submitted as an attachment to the city for review/approval. It must be approved prior to issuing a C of O.
12/18/2024 COT - RSBU - Roof Nailing  Passed 12/18/24 bracing at truss H10A have been made. Roof nailing Approved. EWS