Permit: TC-MDP-0823-01386

Parcel: 141450630

Inspection Status: Passed

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 1/3/2024 corrections were made.
12/29/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Ufer not connected to GEC, use proper rated electrical box for electrical wire at water heater, foam top plate at front of garage, wiring not complete in living room, nail plates needed at second floor room front of house, electrical not complete.