Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | Dwv not on test. Missing ground screw at pancake box outside of first bedroom. Add Boca plate to 2" line kitchen sink. Add brace to 2" line above ceiling at laundry room. Secure exhaust duct at laundry room. Add supports to line sets. Primary room receptacle exceeding 12'. Add fha plate to bottom plate at primary bathroom. Secure exhaust fan in primary bathroom. Secure fresh air intake. Stopped inspection. Other items may apply. 10/9/2026 | |
| 10/13/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 10/13/2026 Corrections made, walked rest of upstairs. |