Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Anchor bolts at marked locations throughout, sister damaged stud in kitchen marked, add shims in marked area at garage, per plans sliding glass doors should have 2 jack studs. STOPPED INSPECTION MORE ITEMS MAY BE ADDED | |
| 03/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 28 March 25 All corrections made. |