Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 10/14/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Fill in concrete at porch column. 2x4 blocks call for 12" o.c above shear wall in garage. Add h25 clip at truss in bathroom hall. Add shot pins to interior walls at marked areas. Loose shear wall at master suite. Add anchor bolts at marked areas. Missing headers and cripple studs at both windows north wall. Htt4´s are not in place. 10/14/2024 |
| 10/16/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Corrections were made. 10/16/2024 |