Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 11/22/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
11/22/24. Multiple branch circuits are tied together, check gusset plates, where wires are running across. Fire foam chases on second floor, check all penetrations at vapor barriers. Gas line not secured throughout. Seal penetrations between floors, stud shoes required at 2"x6" studs where pvc runs through, ceiling fixture requires correct screws. |
| 11/26/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
11-26-24, all items requiring corrections have been rectified. Residential intermediates approved. |