Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 12/06/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
12-6-24, exterior garage coach light metal box is overfilled. Box is rated for 6 cubic inches and there are 2 14/2 awg wires. Missing fire foam at foyer, stair case/kitchen area, and dwv on first floor not under pressure. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. |
| 12/10/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
12/10/24 wires bundled together against code, incorrect screws in fan boxes, must use provided hex screws, missing fire foam in downstairs bedroom. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. |
| 12/12/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
Corrections made 12/12/24 |