Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/19/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8-19-26 fix sthd10 hold down spalling right of garage exterior* add shot pins to marked location throughout* add anchor bolt to Marked locations around perimeter throughout also anchor bolts should be driven in middle third of 2 x 4 sole plate* RSP4 missing at east wall exterior* trimmer stud nail to King stud shall be 8 inches on center at all window framing areas throughout refer t detail sn4 13.a* H2 .5 missing at optional Den bedroom four at West wall* stopped inspection at this time. More items may be added truss calcs. And roof Nailing was not walked
08/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 8-20-26 all corrections have been made OK to continue