Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 12-11-25: missing nails on exterior sheathing at a few locations- plans call for 6" o.c. Along edges and 12" o.c. In the field, add shot pins within 6" at the ends of plate, add backing at bathtub-see plans for details, add an anchor bolt at marked location west wall, add nails to lose roof panels at marked areas. | |
| 12/12/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 12-12-25: add nails at exterior 6" o.c. Along edges/splices-north side of home above window add nails, add shot pins within 6" at the ends of each plate. | |
| 12/16/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 12/16/2025 All corrections made from prior 12/12/25 inspection. |