Permit: TC-MDP-0525-00316

Parcel: 13705074F


Addresses:

456 W WYOMING ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
12/11/2025 COT - RSBU - Roof NailingĀ  Re-inspection required 12-11-25: missing nails on exterior sheathing at a few locations- plans call for 6" o.c. Along edges and 12" o.c. In the field, add shot pins within 6" at the ends of plate, add backing at bathtub-see plans for details, add an anchor bolt at marked location west wall, add nails to lose roof panels at marked areas, add gable end bracing at center-cannot exceed 25'.
12/12/2025 COT - RSBU - Roof NailingĀ  Passed 12-12-25: okay to dry-in roof.