Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Yard Water Line
| Date |
Description |
Inspector |
Results |
Comments |
| 05/21/2025 |
COT - RSPL - Yard Water Line |
|
Re-inspection required |
5-21-25, underground plumbing verified per plans. However, trench shall be free of debris, rocks, loose dirt, and all plumbing joints must be visible. Rocky unstable soil shall be over excavated by two pipe diameters and brought to grade with suitable compacted granular material. See P2604.1 of the IRC. |
| 05/22/2025 |
COT - RSPL - Yard Water Line |
|
Partial Pass |
5-22-25: main water line not connect to main. Okay to backfill at own risk. Shading materials required and water will be checked at intermediates. |
| 06/20/2025 |
COT - RSPL - Yard Water Line |
|
Passed |
|