Inspection Status: Canceled
Inspection History: COT - RSBU - Roof Nailing
| Date |
Description |
Inspector |
Results |
Comments |
| 06/09/2025 |
COT - RSBU - Roof Nailing |
|
Canceled |
6-9-25: canceled by contractor |
| 06/10/2025 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
6-10-25: missing RSP4's along southside, add 1" staples to marked areas of t-ply on eastside, missing h-25 at far back bathroom along east truss, missing A-35 at bedroom 2-see SD 4-36 for details, add 1" staple to t-ply at family room-top corner, missing beam to post straps at back porch, add longer straps at front porch with 10 nails top/bottom of interconnecting points, missing A-34's to base of gable end bracing, loose roof panel at family room |
| 06/13/2025 |
COT - RSBU - Roof Nailing |
|
Passed |
6-13-25: approved. |