Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
09/06/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Loose shear wall at garage area. Missing anchor bolts per shear wall schedule. Add h25 clips for 3 point bearing trusses. Missing h25 clip at garage entry along with hanger. Add more nails to cs16 strap from beams to studs. Add nails at interior wall bottom plate stairway 2nd floor. Missing tread. Add blocking at hips. Loose sheathing at hips. 9/6/2024
09/11/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Per previous notes. 9/11/2024
09/13/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass Partial pass. Pending loose shear wall at garage area left side. 1st sheet. Add h25 clip at truss in garage entry. 9/13/2024
10/07/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required
10/09/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Per previous notes. 10/9/2024
10/14/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed