Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0524-00680
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/06/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Loose shear wall at garage area. Missing anchor bolts per shear wall schedule. Add h25 clips for 3 point bearing trusses. Missing h25 clip at garage entry along with hanger. Add more nails to cs16 strap from beams to studs. Add nails at interior wall bottom plate stairway 2nd floor. Missing tread. Add blocking at hips. Loose sheathing at hips. 9/6/2024 | |
09/11/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Per previous notes. 9/11/2024 | |
09/13/2024 | COT - RSBU - Roof Nailing | Passed |