Permit: TC-MDP-0524-00654

Parcel: 140062790


Addresses:

3565 E NEBRASKA SV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/15/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing shear walls. One at 1st bedroom. 2nd at great room area. Shear wall nailing not per schedule. Add anchor bolts to breaks at bottom plates. Add cut nails or shot pins to all loose interior plates. Add fire blocking and secure wall at shower. Add h25 at truss above window great room area and 1st bedroom areas. Add double studs underneath girder truss. Loose roof sheathing at hips. 8/15/2024
08/19/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Corrections were made. 8/19/2024