Inspection Status: Canceled
Inspection History: COT - RSBU - Roof Nailing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/10/2024 |
COT - RSBU - Roof Nailing |
|
Canceled |
Canceled per contractor. 7/10/2024 |
| 07/23/2024 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
Provide anchor bolts near the ones that have been hammered in place. Provide compact drill to screw in titans. Missing braces on trusses. Missing h25 at master walk in closet. Add more nails to rsp clips south of home. Add straps at front patios from headers to trimmers. 7/23/2024 |
| 07/31/2024 |
COT - RSBU - Roof Nailing |
|
Passed |
|