Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0524-00587
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Canceled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/10/2024 | COT - RSBU - Roof Nailing | Canceled | Canceled per contractor. 7/10/2024 | |
07/23/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Provide anchor bolts near the ones that have been hammered in place. Provide compact drill to screw in titans. Missing braces on trusses. Missing h25 at master walk in closet. Add more nails to rsp clips south of home. Add straps at front patios from headers to trimmers. 7/23/2024 | |
07/31/2024 | COT - RSBU - Roof Nailing | Passed |