Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 06/06/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
6-6-25: not ready-still working on it. |
| 06/09/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
6-9-25: straps on beam to post require 10 nails above/below interconnecting points-add larger straps and nails, add staples to t-ply 3" o.c at garage shear wall, 3" o.c. for exterior sheathing at garage, loose roof panel at marked area, add shot pins to marked locations. |
| 06/13/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required (with fee) |
6-13-25: shot pins missing at marked location and add nails to loose roof panel at marked location. |
| 06/17/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|