Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
06/09/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-9-25: missing nails along edges at rim board located on west side/eastside, replace T-ply on east side-too many overpenetrated staples, check spacing on T-ply at east side & at southwest side-plans call for 3" o.c., add shot pins to marked locations, and anchor bolts at garage area. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED.
06/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-10-25: add nails to marked areas at sill plate to floor decking on second floor, replace t-ply on northeast side, add nails to rim board on east/west sides, missing rsp4 on west side of garage.
06/13/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required (with fee) 6-13-25: rsp4 on west that was marked by me and framing supervisor not replaced, nails on upstairs decking not nailed flush at marked locations, t-ply on east side was marked to be replaced and wasn't , 1" staples required at 3" o.c. at splices/edges at upstairs north area, loose shear wall at upstairs west side, rim board on east side has countless overpenetrated nails throughout at edges- can't overpenetrated more than 1/8". Make corrections and reschedule.
06/16/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass 6-16-25: make corrections to t-ply located on northeast corner of home-add blocking and staple 3" o.c. along edges. Okay to proceed to with construction except at area requiring correction. Reschedule inspection for t-ply prior to covering.
06/17/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed