Permit: TC-MDP-0425-00225

Parcel: 141450490

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
07/23/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 7-23-25: add shot pins together with anchor bolts at marked areas. Add nails to exterior sheathing 6" o.c. /12" in the field-several areas along the belly board and elsewhere are either missing nails per schedule and or are overpenetrated.Most areas are marked but do a thorough walk thru.
07/25/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 7/25/25
Pass