Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Underground 

Date Description Inspector Results Comments
06/06/2024 COT - RSEL - Electrical Underground  Re-inspection required 6/6/24: all reinforcement must maintain a 3" clearance from earth (making contact in multiple locations), exterior post footings missing per plan, plumbing wrap missing plastic piping.
06/10/2024 COT - RSEL - Electrical Underground  Passed 6/10/24: post tension cabling is properly installed, rebar reinforcement is in place and held up by chairs to maintain the 3" clearance, Ufer ground is in place, and all plumbing pipes are properly wrapped with foam to protect against concrete damage. Underground electrical is installed for kitchen island. Okay to pour concrete.