Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0424-00459

Parcel: 136480110


Addresses:

9781 E GRAY HAWK DR

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
07/01/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Exterior walls are properly secured to concrete floor with shot pins, a/b bolts, and masa clips. Shear wall is properly secured per the plan. Okay to proceed with plumbing, mechanical, and electrical rough-in.