Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/27/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024 | |
08/30/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024 8/30/24: Sister 2x6 stud above foyer, properly secure anchor bolts, blocking at stairwell landing. |
|
09/09/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 9/9/2024 corrections were made. Approved. |