Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024 | |
| 08/30/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024 8/30/24: Sister 2x6 stud above foyer, properly secure anchor bolts, blocking at stairwell landing. |
|
| 09/09/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9/9/2024 corrections were made. Approved. |