Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0424-00395

Parcel: 141435440


Addresses:

6724 E VIA DE AYATE

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/27/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024
08/30/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024
8/30/24: Sister 2x6 stud above foyer, properly secure anchor bolts, blocking at stairwell landing.
09/09/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9/9/2024 corrections were made. Approved.