Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141435440


Addresses:

6724 E VIA DE AYATE


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0424-00395

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/27/2024 COT - RSBU - Roof Nailing  Re-inspection required Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024
08/30/2024 COT - RSBU - Roof Nailing  Re-inspection required Add anchor bolts to extMissing studs at our 3pt bearing floor GT. Add 2x studs tu those that have been compromised. Kitchen area and first bedroom. Add rsp clips from bottom plates to post. (4x6's). Missing jack studs at SGD. Sister 2x6 stud above foyer. 8/27/2024
8/30/24: Sister 2x6 stud above foyer, properly secure anchor bolts, blocking at stairwell landing.
09/09/2024 COT - RSBU - Roof Nailing  Passed 9/9/2024 corrections were made. Approved.