Permit: TC-MDP-0326-00159

Parcel: 141461770


Addresses:

9642 E WYNALDA DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Interior Shear BracingĀ 

Date Description Inspector Results Comments
07/10/2026 COT - RSBU - Interior Shear BracingĀ  Re-inspection required 7-10-2026 fasteners need to be no less then 3/8" from edge [throughout] fastener should not penetrate drywall more than eighth of an inch (1/8") also fasteners should be placed at 12 inches on center throughout. Please re-walk before calling it in. Sheer wall was correct.
07/13/2026 COT - RSBU - Interior Shear BracingĀ  Passed 07/13/2026
Corrections made.