Permit: TC-MDP-0325-00187

Parcel: 141461340


Addresses:

9610 E MEOLA DR

Inspection Status: Not Ready

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
07/27/2026 COT - RSEL - Electrical Final  Not Ready Outdoor lighting missing fixture. Provide grommet along with ground screw at metal box. Properly secure switch underneath kitchen sink. T stat she’ll be at 48”. Smoke detectors to close to the wall both north bedrooms. Provide proper slope at drain pan. Label heat kit if installed. Or none if not. Remove all construction debris. Extend primary condensation line. Provide 3” clearance around a/c unit. Ensure all conditions are met prior to final. 7/27/2026
07/28/2026 COT - RSEL - Electrical Final  Passed 07/28/2026
All corrections made to prior inspection. Partial pass pending open conditions paperwork.