Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Interior Shear BracingĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 06/09/2026 |
COT - RSBU - Interior Shear BracingĀ |
|
Re-inspection required |
6/9/26: fasteners at shearwalls not spaced per approved plans throughout, all fasteners shall be no closer than 3/8" from edge. Fasteners shall penetrate no more than 1/8", receptacle at master bathroom covered, spacing for fasteners must be corrected throughout. Fasteners tearing drywall have no value and shall have 1 fastener above and below the torn area. |
| 06/11/2026 |
COT - RSBU - Interior Shear BracingĀ |
|
Passed |
|