Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
09/11/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Add anchor bolts at break in the bottom plates no more than 12" and per shear wall schedule. Missing hanger at girder truss 2nd floor. Loose shear wall at garage and second floor north end near window. Add rsp clips at bottom plates to columns. Plans call for x2 cs16's at front end shear wall. Add stud in garage for 12" o.c. 9/11/2024
09/13/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Corrections were made. 9/13/2024