Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0324-00345
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Add anchor bolts at break in the bottom plates no more than 12" and per shear wall schedule. Missing hanger at girder truss 2nd floor. Loose shear wall at garage and second floor north end near window. Add rsp clips at bottom plates to columns. Plans call for x2 cs16's at front end shear wall. Add stud in garage for 12" o.c. 9/11/2024 | |
09/13/2024 | COT - RSBU - Roof Nailing | Passed | Corrections were made. 9/13/2024 |