Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 04/02/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Add anchor bolts at marked locations, tighten down all anchor bolts. Anchor bolts at SW11 or greater should have 3" plate washers, sister damaged studs at E and W side of house marked, nail loose stud to ceiling at W side, marked. Provide engineering fix for damaged A2 truss near back patio. STOPPED INSPECTION MORE ITEMMS MAY BE ADDED |
| 04/08/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Anchor bolts at SW11 or greater should have 3" plate washers, sister damaged studs at E and W side of house marked |
| 04/09/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
4-9-25, exterior clips/sheathing approved. Okay to continue with construction. |