Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
|
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
9-8-25: pex to can lights require a 12" clearance-block with osb, plywood, drywall or relocate lines allowing for required clearance. Firefoam all penetrations, add an additional strap for DWV at bracing for laundry room, fix tears to flex at bedroom east of laundry room. |
| 09/09/2025 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
9-9-25: intermediates approved. Okay to continue with construction. |