Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0224-00165
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Caulk all exterior penetrations through lath. Provide FHA plate or two cs16 strap on both sides to top plate at dryer duct. Move over electrical wiring from gusset plates. Add FHA plate and seal top plate behind kitchen hood. Refrigerator calls to be dedicated circuit. 9/26/2024 | |
10/02/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Caulk all exterior penetrations through lath. Provide FHA plate or two cs16 strap on both sides to top plate at dryer duct. Move over electrical wiring from gusset plates. Add FHA plate and seal top plate behind kitchen hood. Refrigerator calls to be dedicated circuit. 9/26/2024 10/2/24: pending corrections, secure NM cable 12" from box, multiple circuits tied together, furnace vent damaged must be replaced, thermostats must be no higher than 54" above finish floor, H2.5 removed by kitchen hood must be replaced, |
|
10/07/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Multiple circuits tied together. 10/7/2024 | |
10/08/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | Partial pass. Revision will be sent in to match electrical plans at final. Okay to proceed at own risk. 10/8/2024 |