Permit: TC-MDP-0126-00016

Parcel: 14101013E


Addresses:

9993 E LEBARON DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
04/07/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 04/07/2026
Add anchor bolts at marked locations, SW11 in rear requires steel washer plates and interior SW11 and SW13 on the two added anchor bolts need washers. Rear patio does not call for pocket beam into SW11, instead calls for HUC26-2 hanger per covered patio option #2 plan. Could not verify truss calcs with 2212 plans provided, field assembly has A1 trusses for 2685 Elevation B plan.
04/08/2026 COT - RSBU - Roof NailingĀ  Passed 04/08/2026
Corrections made to prior inspection. Verified truss calcs and bracing.