Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Excavation/Rebar/Zoning 

Date Description Inspector Results Comments
03/05/2026 COT - RSBU - Excavation/Rebar/Zoning  Re-inspection required 3-5-26: West & south east setback not per plans-measured at 13' 9"& 12' 3". Footing excavation depth at a few areas is not per plans, re-compact pad primarily along edges of footing & around DWV, remove loose dirt from footing. Either provide property pins or submit an updated site plan.
03/06/2026 COT - RSBU - Excavation/Rebar/Zoning  Passed 3/6/2026 string line was in place to verify proper line as the current fence is at a curb. All other corrections were made. Okay for concrete placement.