Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
04/29/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4/29/25: MASA clips require 7 nails minimum when replacing 1/2" A.B, Anchor bolt spacing shall be no greater than 6' o.c, missing king studs at back porch entrance. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4/29/25: MASA clips require 7 nails minimum when replacing 1/2" A.B, Anchor bolt spacing shall be no greater than 6' o.c, missing king studs at back porch entrance. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
5/1/25: Anchor bolts required where masa clips only have 6 nails installed (7 minimum), shot pins missing throughout 6" from edge and 36" o.c, anchor bolts required 12" from edge. Anchor spacing at shear wall not per plan,
05/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Canceled
05/07/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 5/7/25 corrections made