Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 4/29/25: MASA clips require 7 nails minimum when replacing 1/2" A.B, Anchor bolt spacing shall be no greater than 6' o.c, missing king studs at back porch entrance. STOPPED INSPECTION MORE ITEMS MAY BE ADDED | |
| 05/01/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 4/29/25: MASA clips require 7 nails minimum when replacing 1/2" A.B, Anchor bolt spacing shall be no greater than 6' o.c, missing king studs at back porch entrance. STOPPED INSPECTION MORE ITEMS MAY BE ADDED 5/1/25: Anchor bolts required where masa clips only have 6 nails installed (7 minimum), shot pins missing throughout 6" from edge and 36" o.c, anchor bolts required 12" from edge. |
|
| 05/05/2025 | COT - RSBU - Roof Nailing | Canceled | ||
| 05/07/2025 | COT - RSBU - Roof Nailing | Passed | 5/7/25 corrections made |