Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0124-00096

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 2/28/24: missing lateral bracing. Missing shear wall in bedroom 2. Bedroom 2 missing closet. Missing nailing at trust clips throughout house.
03/04/2024 COT - RSBU - Exterior Clips/Sheathing  Passed 3/4/24: all corrections made