Permit: TC-MDP-0124-00079

Parcel: 140442760


Addresses:

6139 E CAMPOLINA TR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
03/31/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 3.31.26
Simpson htc4 clips are missing/improperly spaced throughout per D2 Detail

Staples at tply are over penetrated and improperly spaced at multiple locations, some examples have been marked in red but more persist

Anchor bolts must be in center 3rd of floor plate

INSPECTION STOPPED - BE ADVISED THAT MORE ITEMS MAY BE ADDED
04/01/2026 COT - RSBU - Roof NailingĀ  Passed