Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/09/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready 8/9/24: No plans on site. Please reschedule the inspection.
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8/13/24: follow header schedule interior at windows and closet framing.
08/15/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8/9/24: No plans on site. Please reschedule the inspection.
8/13/24: follow header schedule interior at windows and closet framing.
8/15/24: trimmer studs at headers must be continuous and make full contact with header, window sills should beg at 44" max (do not meet egress requirements), Simpson H2.5 missing at headers (per plan), interior bearing headers not per plan, fire blocking around soffits required.
08/19/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed