Inspection Status: Canceled
Inspection History: COT - LCEL - Electrical Intermediate
| Date |
Description |
Inspector |
Results |
Comments |
| 05/27/2026 |
COT - LCEL - Electrical Intermediate |
|
Canceled |
5-27-26: canceled by contractor. |
| 08/31/2026 |
COT - LCEL - Electrical Intermediate |
|
Re-inspection required |
8-31-26: in wall rough electrical-missing low in wall electrical receptacles at west wall, add pigtails to ground screws to in wall receptacles throughout, provide vertical supports for rmc at 10' intervals and within 12" of a receptacle box. We will look at the above required corrections at intermediates. |
| 09/30/2026 |
COT - LCEL - Electrical Intermediate |
|
Partial Pass |
9/30/2026 Partial pass. Power outlets per plan at service counter area. Okay to proceed with progress areas. |