Inspection Status: Partial Pass
Inspection History: COT - LCBU - Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 06/25/2026 |
COT - LCBU - Framing |
|
Partial Pass |
6-25-26: partial pass- install washers at all hold downs, missing lsta36 between header & jack studs-loop over header to opposite side-see S001 Detail 7. Need to verify all A35's per same detail. Missing edge nailing at decking/parapet at several areas. Reschedule inspection at your convenience. |
| 06/26/2026 |
COT - LCBU - Framing |
|
Partial Pass |
6-26-26: framing for shell approved. Okay to continue with construction at progress areas. |