Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 13815015C


Addresses:

6675 S 12TH AV


Inspection Status: Partial Pass

Inspection History: COT - HCBU - Building Progress

Permit Number - TC-COM-1224-02387

Inspection Description - COT - HCBU - Building Progress

Inspection Status - Partial Pass

Date Description Inspector Results Comments
01/08/2026 COT - HCBU - Building Progress Partial Pass 1-8-26: drywall screw inspection room's 324, 323, 322, 321, 313-missing section of drywall above ceiling at hallway, 312, 311-drywall missing at window approved. Okay for tape & texture progress areas but reschedule inspection for room's 311 & 313 when ready.
01/20/2026 COT - HCBU - Building Progress Partial Pass 1-20-26: shower test for Section A, 1st. Floor. Okay to continue with construction in all rooms with the exception of Room's 101, 128, and 125 which were not ready.
01/23/2026 COT - HCBU - Building Progress Partial Pass 1-23-26: drywall screw inspection at room's 216, 217, 218, 215, 214, 219, 220-finish drywall at bedroom soffit. Okay to continue with tape & texture at progress areas.
01/28/2026 COT - HCBU - Building Progress Partial Pass 1-28-26: drywall screw inspection-room's 224, 211, 212, 223, 222, 213, 221. Okay to tape & texture drywall.
02/02/2026 COT - HCBU - Building Progress Partial Pass 2.2.26
Screw inspection at shear for:
301
328
327
308
326
309
325
310
Also verified dead space drywall screw inspection at stairwells. Okay to tape & texture progress areas.
02/13/2026 COT - HCBU - Building Progress Partial Pass 2-13-26: intermediate reinspect units 121-124 111-115 approved. Add nails at south stairwell per schedule at each level. North stairwell dead space approved. Okay to cover,progress areas.
02/18/2026 COT - HCBU - Building Progress Partial Pass 2-18-26: drywall nailing for Room A14-East wall only, 201, 202, 207, 206, 203, 204. Okay for tape & texture.
02/19/2026 COT - HCBU - Building Progress Not Ready 2-19-26: reschedule inspection. Note: I can only inspect a total of 7 units at any given time.
02/20/2026 COT - HCBU - Building Progress Canceled 2-20-26: canceled by contractor.
02/23/2026 COT - HCBU - Building Progress Partial Pass Partial pass. West center stairwell. Interior drywall shear approved. Okay to proceed progress areas. 2/23/2026
05/16/2025 COT - HCBU - Building Progress Partial Pass 5/16/25: PRE-CON MEETING.
05/29/2025 COT - HCBU - Building Progress Not Ready
12/29/2025 COT - HCBU - Building Progress Re-inspection required 12-29-25: drywall shear inspection on room's 314-320. Add screws 7" o.c. Field and along edges. Add screws where screws are 3/8" from edges/joints and cannot over penetrate more than 1/32".