Parcel: 13815015C


Addresses:

6675 S 12TH AV


Inspection Status: Re-inspection required

Inspection History: COT - HCEL - Electrical Intermediate

Permit Number - TC-COM-1224-02387

Inspection Description - COT - HCEL - Electrical Intermediate

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/09/2026 COT - HCEL - Electrical Intermediate Re-inspection required 1-9-26: MEP's for 2-floor, Section B- Units 220- adjust/move or add receptacle at kitchen wall (receptacles are required to be installed within 30" of the stove at each side). 219-fire foam penetration at top plate above stove, fire foam horizontal penetration at same area-party wall, fire foam penetration above window, fire foam penetration at top plate restroom, 218-strap DWV, fire foam penetration at top plate. Fire foam all horizontal penetrations at party walls and all vertical penetrations where coil straps penetrate floors. Apply wool at restroom DWV's or fire foam penetrations at top plates in all units. Provide size of smart electrical box above ceiling in hallways to verify box fill. Reschedule inspection for MEP's when ready.
01/13/2026 COT - HCEL - Electrical Intermediate Partial Pass Section B; Level #2; Room units 211 - 224. OK to insulate and sheet rock interior walls.
01/20/2026 COT - HCEL - Electrical Intermediate Canceled 1-20-26: canceled by contractor.
01/21/2026 COT - HCEL - Electrical Intermediate Re-inspection required 1/21/26: M.E.P inspections conducted (in unit# 310,325,309,326,308,327,328), properly support NM cable at chase near restrooms, seal all penetrations through top plates/draft stop/corridor wall, Properly insulate all hot water piping 3/4" or larger, properly seal all rated assemblies at mechanical areas in hallways, receptacle spacing in bedroom in unit 325 shall be spaced not greater than 12', properly secure all dryer vent ducts in-wall, properly seal all openings at chase near restrooms, nail plates required throughout where electrical/plumbing come within 1 1/4" from face of stud, seal penetration near water closet at all bathrooms,
01/22/2026 COT - HCEL - Electrical Intermediate Canceled 1-22-26: canceled by contractor.
01/23/2026 COT - HCEL - Electrical Intermediate Partial Pass 1-23-26: reinspected MEP's at room's 310,325,309,326,308,327,328. All corrections made-okay to continue construction at progress areas.
01/28/2026 COT - HCEL - Electrical Intermediate Partial Pass 1-28-26: MEP's at room's 301, 302, 307,306, 303-staple electrical, 304- fire foam/firecaulk penetrations along the east side wall party wall , 305- seal penetration at restroom penetration top plate at dwv. Add grounding screws to all metal pancake boxes in all rooms. Okay to continue construction at progress areas but listed above items need a reinspect prior to covering.
01/30/2026 COT - HCEL - Electrical Intermediate Partial Pass 1-30-26: MEP's 2nd floor, room's 228, 227, 208, 226, 209, 210, 225 verified per plans. Okay to continue with construction at progress areas.
02/02/2026 COT - HCEL - Electrical Intermediate Partial Pass 2-2-26: electrical intermediate on all 3 stairwells approved.
COT - HCEL - Electrical Intermediate Scheduled
12/03/2025 COT - HCEL - Electrical Intermediate Partial Pass 12-3-25: partial pass on electrical intermediate inspection on 3rd floor Section B rooms, 316, 317, 315, 318, 314, 319, 320. Okay to continue with construction at progress areas.
12/04/2025 COT - HCEL - Electrical Intermediate Partial Pass 12-4-25: partial pass for in wall electrical intermediates at room's 321, 313, 322 323, 312, 311,314. Okay to continue with construction at progress areas.