Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - HCEL - Electrical Progress
Permit Number - TC-COM-1224-02366
Inspection Description - COT - HCEL - Electrical Progress
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/13/2026 | COT - HCEL - Electrical Progress | Partial Pass | 3-13-26: in wall electrical approved-okay to install first layer of 5/8" drywall at progress areas. Schedule a drywall screw inspection prior to tape & texture. | |
| 03/19/2026 | COT - HCEL - Electrical Progress | Not Ready | 3/19/2026 not ready. Room #c119. Extend electrical boxes so that when it's time for drywall they'll be flushed. Fire caulk all penetrations above ceiling into firewalls. No bundling more than 4 wires per hole. Smoke detectors not set in place along with kitchen receptacles. Secure loos wires vertically. |