Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - HCBU - Building Progress
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2024 | COT - HCBU - Building Progress | Partial Pass | 8/9/24: opening per plans ok to proceed with footing and apron per plans. | |
| 08/29/2024 | COT - HCBU - Building Progress | Partial Pass | 8/9/24: opening per plans ok to proceed with footing and apron per plans. 8/29/24: reinforcement at apron not per plans, overlap must be 24" min, spacing of #4 rebar calls for 16" o.c, footing depth not per plan. 8/29/24: corrections made ok to proceed with apron, |
|
| 08/29/2024 | COT - HCBU - Building Progress | Re-inspection required | 8/9/24: opening per plans ok to proceed with footing and apron per plans. 8/29/24: reinforcement at apron not per plans, overlap must be 24" min, spacing of #4 rebar calls for 16" o.c, footing depth not per plan. |
|
| 10/30/2024 | COT - HCBU - Building Progress | Passed |