Inspection Status: Re-inspection required
Inspection History: COT - HCPL - Plumbing Intermediate
| Date |
Description |
Inspector |
Results |
Comments |
| 08/12/2025 |
COT - HCPL - Plumbing Intermediate |
|
Re-inspection required |
8-12-25: firefoam penetrations at top plates and firefoam any penetrations from an unconditioned space to a conditioned space, add straps to pex at north wall and 4x8" boca plates to DWV. Note: some areas were marked but not all.Walk site and add Boca plates where required. Also, where DWV runs through plates and have been notched more than 60% then FHA plates are required. That space in between must be firefomed too. This includes electrical as well. |
| 08/13/2025 |
COT - HCPL - Plumbing Intermediate |
|
Re-inspection required |
8-13-25: firefoam penetrations throughout. |
| 08/14/2025 |
COT - HCPL - Plumbing Intermediate |
|
Partial Pass |
8-14-25: add Boca plates at top plates to protect DWV. Boca plates to be verified prior to installation of interior wall finish. Okay to continue with construction at progress areas. |
| 12/16/2025 |
COT - HCPL - Plumbing Intermediate |
|
Passed |
|