Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-COM-1122-00167

Parcel: 13614004B


Addresses:

7975 E STELLA RD

Inspection Status: Partial Pass

Inspection History: COT - HCBU - Masonry Pregrout 

Date Description Inspector Results Comments
08/05/2024 COT - HCBU - Masonry Pregrout  Partial Pass 2 courses of CMU block have been laid for stem wall with #6 rebar reinforcement installed. Okay to grout stem wall.
08/19/2024 COT - HCBU - Masonry Pregrout  Partial Pass 8/19/24: first lift on north west side of building okay to grout. Two courses on east side stem wall okay to grout
08/22/2024 COT - HCBU - Masonry Pregrout  Partial Pass 8/22/24: okay to grout second lift west side of building.
08/30/2024 COT - HCBU - Masonry Pregrout  Partial Pass 8/30/24: Okay to grout 3rd lift on NW addition.
09/05/2024 COT - HCBU - Masonry Pregrout  Partial Pass 9/5/24: okay to grout and cap final lift on north side of building exercise room.
11/21/2024 COT - HCBU - Masonry Pregrout  Partial Pass Bond beam in place. Remaining two courses for stem wall on east end of building approved. Okay to grout progress areas. 11/21/2024
12/12/2024 COT - HCBU - Masonry Pregrout  Partial Pass 12-12-24, verified rebar as per approved plans.Okay to grout stem wall at 4 feet on southeast area of site
12/16/2024 COT - HCBU - Masonry Pregrout  Partial Pass 12-16-24, east and south wall on 2nd course-okay to grout (8 feet). North wall at 1course (4 feet) and is okay to grout.
12/18/2024 COT - HCBU - Masonry Pregrout  Partial Pass 12-18-24, north wall height at 8 feet. Okay to grout 2nd course.
12/19/2024 COT - HCBU - Masonry Pregrout  Partial Pass 12-19-24, rebar verified at 24"o/c for east stem wall. Okay to grout 3rd course at 13 feet.
12/20/2024 COT - HCBU - Masonry Pregrout  Passed 12/20/24, rebar verified at 24"o/c for North wall. Okay to grout 3rd course at 13 feet.